AFIDA – Indicated Cetane Number Analyser - SA6000-0
AFIDA – Indicated Cetane Number Analyser - SA6000-0
Methods
BIS IS 1448-9
ASTM D613
ASTM D6751
ASTM D7467
ASTM D8183
ASTM D975
BS EN 17155
BS EN ISO 5165 & BS 2000-41 & ISO 5165
IP 41
IP 617
Features
- Indicated Cetane Number by CVCC
- Range 35-85 ICN
- Highly automated with auto sampler
- Primary Reference Fuel Calibration
- No bias correction to engine values
- Excellent precision, minimal giveaway
- Easy to use, suitable for 24/7 operation
- Load and go
AFIDA Ambered Vials (pack of 100) - SA6003-001
AFIDA Ambered Vials (pack of 100) - SA6003-001
Methods
ASTM D613
ASTM D6751
ASTM D7467
ASTM D8183
ASTM D975
BS EN 17155
BS EN ISO 5165 & BS 2000-41 & ISO 5165
IP 41
IP 617
Features
- Pack of 100 ambered vials
- For use with the AFIDA SA6000-0)
AFIDA Septums for Sample Vials (pack of 100) - SA6003-002
AFIDA Septums for Sample Vials (pack of 100) - SA6003-002
Methods
ASTM D613
ASTM D6751
ASTM D7467
ASTM D8183
ASTM D975
BS EN 17155
BS EN ISO 5165 & BS 2000-41 & ISO 5165
IP 41
IP 617
Features
- Pack of 100 vials
- For use with ambered sample vials SA6003-001
Verification Fluid (pack of 4) - SA6009-0
Verification Fluid (pack of 4) - SA6009-0
Methods
ASTM D8183
BS EN 17155
IP 617
Features
- Pack of 4 x 40 ml verification fluid vials
- For use with the AFIDA SA6000-0
Seta Silver and Copper Corrosion Bath – 11405-0
Seta Silver and Copper Corrosion Bath – 11405-0
Methods
ASTM D130
ASTM D4048
ASTM D4814
ASTM D7667
ASTM D7671
BIS IS 1448-15
IP 154
IP 611
BS 2000-112 & IP 112
BS EN ISO 2160 & BS 2000-154 & ISO 2160
Features
- Ambient +5 to 150 °C
- 22 litre bath
- Six test stations
- Programmable digital temperature controller
- Digital timer
- Over temp cut out & liquid level float switch
- Maximum liquid level outlet fitting
- Small footprint
Seta Copper Silver Block Bath - 11310-0
Seta Copper Silver Block Bath - 11310-0
Methods
ASTM D130
ASTM D7667
Features
- Dry heating for up to four test samples
- Holds four 25x150 mm test tubes
- Operator selected test set point temperature
- Stability ±0.1 °C
Seta Oxi-Cor Bath - 15550-3
Seta Oxi-Cor Bath - 15550-3
Methods
BIS IS 1448-15
BIS IS 1448-147
ASTM D130
ASTM D4048
ASTM D4814
ASTM D525
ASTM D5304
ASTM D7667
ASTM D7671
ASTM D873
BS 2000-112 & IP 112
BS 2000-138 & IP 138
BS EN ISO 2160 & BS 2000-154 & ISO 2160
BS EN ISO 7536 & BS 2000-40 & ISO 7536
DIN EN ISO 2160
DIN EN ISO 7536
IP 154
IP 227 (obs)
IP 40
IP 611
Features
- Stainless steel water or oil bath
- Ambient +5 to 150 °C temp range
- Four test stations (Three when used for Oxidation tests)
- Copper/Silver Corrosion and Oxidation tests
- Optional automatic pressure monitoring
- Integral over-temperature and low fluid level protection devices
Salt in Crude Analyser - 99700-6
Salt in Crude Analyser - 99700-6
Methods
ASTM D3230
IP 265
Features
- Pre calibrated for immediate use to ASTM D3230
- Salt concentration values displayed automatically
- No need for mixing of salt standards
- Typical test time of less than 30 seconds
- Calibration modes allow verification using user standards
- Fully portable
H2S Analyser with VPP - SA4000-4
H2S Analyser with VPP - SA4000-4
Methods
ASTM D7621
IP 570
ISO 8217
Features
- Measurement range from 0-250 mg/kg H2S (0-250 ppm H2S) in the liquid phase
- Vapour Phase Processor proven to eliminate effects of chemical interference
- A non chemical method, no wet chemistry involved
- Small lab bench footprint, fully portable operation
- Suitable for monitoring residual marine fuel blends, Crude Oil, refinery feedstock components, cargoes & products in the distribution system
- Critical Measurement method for Product Safety and Release
Oil Test Centrifuge – 4 place - 90000-3
Oil Test Centrifuge – 4 place - 90000-3
Methods
ASTM D1290
ASTM D1796
ASTM D2273
ASTM D2709
ASTM D2711
ASTM D4007
ASTM D893
ASTM D91
ISO 3734
ISO 9030
Features
- Specially designed for testing oils
- Heated chamber, ambient to 80 °C
- 4 place swing out rotor
- Optional trolley
- Pre-heat facility to ensure bowl is at test temperature prior to test
- Universal buckets for 12.5 ml, 6 and 8 inch glassware
- Microprocessor control with 99 memories
- 6 place centrifuge available (90100-0)
SetaVap4 Automatic Vapour Pressure Analyser - 80600-2
SetaVap4 Automatic Vapour Pressure Analyser - 80600-2
Methods
ASTM D5191
IP 394
ASTM D5188
ASTM D6378
ASTM D6377
ASTM D6897
EN 13016-1
EN 13016-3
ASTM D8009
Features
- Rapid, automatic testing
- Simple test procedure
- Compact, rugged design for portable or laboratory use
- Real time display of test progress and storage for 500,000 results
- LIMS connectivity and RS232C serial port, results can be saved to USB or transferred via QR code
- Statistical Quality Control (SQC) software to analyse results to conform to ASTM D6299
- Test multiple temperatures and multiple V/L ratios (ASTM D6377)
FAME in Jet Fuel – FIJI - SA5000-2
FAME in Jet Fuel – FIJI - SA5000-2
Methods
ASTM D1655
ASTM D7797
IP 583
Features
- Measures presence of all FAME types C8-C22
- Approved for co-processed fuels
- Analysis time 20 minutes
- 50 ml sample volume
- No hydrocarbon cleaning solvents required
- Laboratory and field instrument
- Suitable for untrained operators
FIJI MF – FAME in MultiFuels - SA5200-0
FIJI MF – FAME in MultiFuels - SA5200-0
Methods
ASTM D1655
ASTM D7797
ASTM D7963
DEF STAN 91-091
IP 583
ISO 8217
Features
- Measures presence of all FAME types C8-C22
- Analysis time 20 minutes
- 50 ml sample volume
- Approved for co-processed fuels
- No hydrocarbon cleaning solvents required
- Laboratory and field instrument
- Suitable for untrained operators
SetaCheck Biodiesel Plus - SA5550-0
SetaCheck Biodiesel Plus - SA5550-0
Methods
ASTM D8274
IP 639
Features
- 0.1% to 80% measurement range
- No dilution required, samples measured directly
- Internal rechargeable battery
- Bright backlit screen displays the Biodiesel concentration (% by volume)
- Can store both a factory and a local calibration
- User calibration available via PC software
- Includes optional built-in 9:1 dilution mode
- Correlates with EN 14078
PM-93 Pensky-Martens Flash Point Tester - 35000-0
PM-93 Pensky-Martens Flash Point Tester - 35000-0
Methods
ASTM D93
BS EN ISO 2719 & BS 2000-34
IP 34
Features
- Easy operation
- Superior safety
- Patented ‘SafeFlash’ auto fire extinguisher
- Complies with ISO 2719 annex b
- Gas or electronic ignition
- Memory storage for 2000 results
- Compact footprint
- Statistical Quality Control software
Setaflash Series 3 Flash Point Tester - 30000-3
Setaflash Series 3 Flash Point Tester - 30000-3
Methods
ASTM D1655
ASTM D3278
ASTM D3828
ASTM D7236
ASTM D8174
ASTM E502
CLP Regulations EC No 1272/2008
EPA 1020 B
IP 523
IP 524
IP 534
ISO 3679
ISO 3680 (Obs)
Features
- 1 minute test, 2 ml sample
- Ambient to 300 °C
- Simple test procedure
- Compact, portable and rugged design
- Automated flash detection
- Automatic barometric pressure correction
- USB port and result storage
- Low cost of purchase and maintenance
Setaflash Series 3e ActiveCool Flash Point Tester - 33220-0
Setaflash Series 3e ActiveCool Flash Point Tester - 33220-0
Methods
ASTM D1655
ASTM D3278
ASTM D3828
ASTM D7236
ASTM D8174
ASTM E502
BS EN ISO 3679 & BS 2000-523
IP 523
IP 524
IP 534
ISO 3680 (Obs)
Features
- Flash / No Flash & Ramp modes
- Electric ignitor
- 10 to 135°C temperature range
- Less than 2 minute test
- Small sample size (2 or 4ml)
- Automatic flash detection
- Electronic peltier cooling
- Portable operation
Setaflash Series 8 ActiveCool Flash Point Tester - 82100-2
Setaflash Series 8 ActiveCool Flash Point Tester - 82100-2
Methods
ASTM D1655
ASTM D3278
ASTM D382
ASTM D7236
ASTM D8174
ASTM E502
BS EN ISO 3679 & BS 2000-523
CLP Regulations EC No 1272/2008
EPA 1020 B
IP 523
IP 534
ISO 3679
ISO 3680 (Obs)
Features
- -30 °C to 135 °C, no external cooling
- 2 ml sample, 1 minute test
- Electric ignition (gas models available)
- Automated flash detection
- Ramp mode for unknown samples
- Fire detection (alarm and relay)
- Peltier heating and cooling
- Automatic barometric pressure correction
H2S Analyser with VPP - SA4000-4
H2S Analyser with VPP - SA4000-4
Methods
ASTM D7621
IP 570
ISO 8217
Features
- Measurement range from 0-250 mg/kg H2S (0-250 ppm H2S) in the liquid phase
- Vapour Phase Processor proven to eliminate effects of chemical interference
- A non chemical method, no wet chemistry involved
- Small lab bench footprint, fully portable operation
- Suitable for monitoring residual marine fuel blends, Crude Oil, refinery feedstock components, cargoes & products in the distribution system
- Critical Measurement method for Product Safety and Release
H2S Vapour Phase Processor Cartridge (pack of 100) - SA4017-100
H2S Vapour Phase Processor Cartridge (pack of 100) - SA4017-100
Methods
ASTM D7621
IP 570
ISO 8217
Features
- Pack of 100 filter cartridges
- One to be used per test
- For use with the Vapour Phase Processor (SA4015-0)
H2S Verification and Calibration Gas (110 litre) - SA4001-001
H2S Verification and Calibration Gas (110 litre) - SA4001-001
Methods
ASTM D7621
IP 570
ISO 8217
Features
- 110 litre canister of 25 ppm Hydrogen Sulfide
- Verification is required every 30 days
- Used to calibrate and verify the H2S Analyser (SA4000-3)
IP 570 PTS Quarterly Membership - SA4032-0
IP 570 PTS Quarterly Membership - SA4032-0
Methods
ASTM D7621
IP 570
Features
- A statistical quality assurance program available in monthly cycles
- Enables laboratories to evaluate their performance for testing liquid phase
- Ability to demonstrate compliance with laboratory accreditation requirements (ISO 17025)
- World-wide inter-laboratory comparison of test results and performance
- Identify any potential equipment or operational bias
- Provides added confidence to laboratory staff and customers
- Reduced potential for dispute
Herschel Emulsifier - 96700-2
Herschel Emulsifier - 96700-2
Methods
ASTM D1401
IP 412
ISO 6614
Features
- 4 independently controlled test stations
- Multiple operator safety features
- Automated test sequence
- No removal of the paddles required
- Guaranteed paddle rotation speed
- Non-reflective enhanced LED lighting
- Small footprint
- Intuitive software package
Air Release Value System - 15840-0
Air Release Value System - 15840-0
Methods
ASTM D3427
BS 2000-313
IP 313
ISO 9120
Features
- Integrated solution
- Multi-station sample handling
- Automated and integrated density monitoring
- Automatic result calculation
- Results storage for over 10,000 tests
- Full LIMS connectivity
- Quick connectors for ease of sample handling
- Automated calibration procedure
AvCountHV - SA1110-0
AvCountHV - SA1110-0
Methods
ISO 60970
ISO 4406
ISO 11171
ASTM D7647
NAS 1638
Features
- High viscosity, up to 1500 mm2/s at 20 °C
- ISO 11171 calibration
- Cumulative counts/ml
- ISO 4406 cleanliness codes
- Dilution ratio calculation
- Real time display of test progress
- LIMS, network and VNC connectivity
- In-field verification and calibration
PM-93 Pensky-Martens Flash Point Tester - 35000-0
PM-93 Pensky-Martens Flash Point Tester - 35000-0
Methods
ASTM D93
BS EN ISO 2719 & BS 2000-34
IP 34
Features
- Easy operation
- Superior safety
- Patented ‘SafeFlash’ auto fire extinguisher
- Complies with ISO 2719 annex b
- Gas or electronic ignition
- Memory storage for 2000 results
- Compact footprint
- Statistical Quality Control software
Oxi Solid Block Bath 4 Way - 16670-0
Oxi Solid Block Bath 4 Way - 16670-0
Methods
ASTM D525
ASTM D873
BS 2000-138 & IP 138
BS EN ISO 7536 & BS 2000-40 & ISO 7536
IP 40
Features
- 4 position
- Dry block
- Digital temperature control
- Over temperature cut out
- Pressure in the vessel can be monitored automatically with the Seta Auto-Oxi Control System (15452-2)
- Small footprint
Water Separation Instrument- WSI Analyser - SA9000-0
Water Separation Instrument- WSI Analyser - SA9000-0
Methods
ASTM D1655
DEF STAN 91-091
ASTM D8073
IP 624
ATA 103
CAN/CGSB-3.23-2020
JIG Bulletin 150
Features
Features
- Fully automated test procedure
- Suitable for untrained operators
- Automated sample mixing for increased accuracy
- Rapid test, no warm up time
- Internal data storage and USB output
- Substantial consumable cost and waste saving
- Field calibration, no down time
Seta Auto-Oxi Control System - 15452-2
Seta Auto-Oxi Control System - 15452-2
Methods
ASTM D525
BS EN ISO 7536 & BS 2000-40 & ISO 7536
IP 40
Features
- Suitable for use with a range of pressure vessels
- Connects to Seta Pressure Transducers via USB hub
- Automatic breakpoint determination
- Connects to Computer via a USB cable
- Incorporates purge and leak test
- With Digital USB thermometer
- Graphical display
WSI Filter Assembly Jig - SA9015-0
WSI Filter Assembly Jig - SA9015-0
Methods
ASTM D8073
IP624
Features
Features
- Cost effective
- Easy to use
- Environmentally friendly
- Easily portable
Seta Auto-Oxidation Stability Bath - 15400-5
Seta Auto-Oxidation Stability Bath - 15400-5
Methods
BIS IS 1448-147
ASTM D525
ASTM D5304
ASTM D873
BS 2000-138 & IP 138
BS EN ISO 7536 & BS 2000-40 & ISO 7536
IP 40
Features
- Operating temperature 100°C
- Water Bath with integral condenser
- 4 test stations
- Cold plunge bath
- Seta Auto-Oxi Automatic Pressure Monitoring
- Integral vessel charge system
- Constant level device
WSI Reference Fluid Base, 97.5 to 100 WSI - SA9004-0
WSI Reference Fluid Base, 97.5 to 100 WSI - SA9004-0
Methods
Features
Features
- Produced in accordance with IP 624 Annex B and ASTM D8073 Appendix X1
- A surfactant-free aviation turbine fuel
- Supplied with full documentation including Safety Data Sheet (SDS)
- 2 year shelf life from date of manufacture
- Use directly and to make reference fluids to cross-check test method performance
- Supplied with a certificate of measurement
WSI Replacement Filters (pack of 50) - SA9001-008
WSI Replacement Filters (pack of 50) - SA9001-008
Methods
ASTM D8073
IP 624
Features
Features
- Single use, individually foil sealed filter material, for ASTM D8073
- A low cost alternative to pre-assembled filter cartridges to help reduce consumable costs
- Re-usable filter cartridge is supplied with each pack
- Easily replaced after each test using the WSI Filter Assembly Tool SA9015-0
Seta Oxi-Cor Bath - 15550-3
Seta Oxi-Cor Bath - 15550-3
Methods
BIS IS 1448-15
BIS IS 1448-147
ASTM D130
ASTM D4048
ASTM D4814
ASTM D525
ASTM D5304
ASTM D7667
ASTM D7671
ASTM D873
BS 2000-112 & IP 112
BS 2000-138 & IP 138
BS EN ISO 2160 & BS 2000-154 & ISO 2160
BS EN ISO 7536 & BS 2000-40 & ISO 7536
DIN EN ISO 2160
DIN EN ISO 7536
IP 154
IP 227 (obs)
IP 40
IP 611
Features
- Stainless steel water or oil bath
- Ambient +5 to 150 °C temp range
- Four test stations (Three when used for Oxidation tests)
- Copper/Silver Corrosion and Oxidation tests
- Optional automatic pressure monitoring
- Integral over-temperature and low fluid level protection devices
AvCount3 Particle Counter - SA1100-0
AvCount3 Particle Counter - SA1100-0
Methods
ASTM D975
ASTM D7467
ASTM D7619
IP 565
IP PM FA
DEF STAN 91-091
DEF STAN 91-86
GOST 17216
ISO 4406
ISO 60970
NAS 1638
Features
- ISO 11171 calibration
- Cumulative counts/ml
- ISO 4406 cleanliness codes
- Dilution ratio calculation
- Real time display of test progress
- LIMS, network and VNC connectivity
- Programmable alarm limits
- 14 embedded test methods
SetaVap4 Automatic Vapour Pressure Analyser - 80600-2
SetaVap4 Automatic Vapour Pressure Analyser - 80600-2
Methods
ASTM D5191
IP 394
ASTM D5188
ASTM D6378
ASTM D6377
ASTM D6897
EN 13016-1
EN 13016-3
ASTM D8009
Features
Features
- Rapid, automatic testing
- Simple test procedure
- Compact, rugged design for portable or laboratory use
- Real time display of test progress and storage for 500,000 results
- LIMS connectivity and RS232C serial port, results can be saved to USB or transferred via QR code
- Statistical Quality Control (SQC) software to analyse results to conform to ASTM D6299
- Test multiple temperatures and multiple V/L ratios (ASTM D6377)
AvCount Lite Particle Counter - SA1800-2
AvCount Lite Particle Counter - SA1800-2
Methods
ASTM D7619
ASTM D975
DEF STAN 91-091
DEF STAN 91-86
IP 565
IP PM FA
ISO 4406
Features
- ISO 11171 calibration
- Cumulative Particles/ml
- ISO 4406 Cleanliness Codes
- Portable, compact instrument
- Online/offline (bottle sample)
- Stand-alone or PC controlled
- Programmable via PC
- Integrated printer
AvCount Lube Particle Counter - SA1900-0
AvCount Lube Particle Counter - SA1900-0
Methods
ASTM D7619
ASTM D7647
GJB 420-1987/420-A-1996/420B-2006
IP 565
ISO 11500
ISO 4406
ISO 60970
Features
- Calibrated to ISO 11171
- Cumulative Particles/ml
- Up to 200 mm2/s viscosity
- FFKM seals compatible with synthetic oils
- Precise and reliable results
- PC controlled or stand-alone
- Ultra compact rugged, steel case suitable for portable use
- Programmable via PC
Crude Oil Manual Piston Cylinder - 80615-0
Crude Oil Manual Piston Cylinder - 80615-0
Methods
ASTM D6377
ASTM D8009
Features
Features
- Enables crude oil samples to be taken from a storage tank, rail car or pipeline
- Up to 1380 kPa (200 psi)
- 500 ml sample volume
- Light weight
- Quick set up
- Easy to use
- Dual scale gauge (psi/kPa)
AvCountHV - SA1110-0
AvCountHV - SA1110-0
Methods
ISO 60970
ISO 4406
ISO 11171
ASTM D7647
NAS 1638
Features
- High viscosity, up to 1500 mm2/s at 20 °C
- ISO 11171 calibration
- Cumulative counts/ml
- ISO 4406 cleanliness codes
- Dilution ratio calculation
- Real time display of test progress
- LIMS, network and VNC connectivity
- In-field verification and calibration
SETA-CRM AvCount Verification Material - SA1006-0
SETA-CRM AvCount Verification Material - SA1006-0
Methods
ASTM D7619
IP 565
IP 630
ISO 11171
Features
- Produced under our ISO 17034 UKAS accreditation
- Characterised in accordance with ISO 11171
- Serves as a Secondary Working Standard (SWS) with a particle distribution traceable to NIST SRM 2806a and 2806d
- Use with Automatic Particle Counters (APCs) calibrated in accordance with ISO 11171 using IP 565, IP 630, and/or ASTM D7619
- Suppled in tamper-evident security packaging with full documentation, including a Safety Data Sheet (SDS)
- 2 year shelf life from the date of manufacture
- 250 mL bottle
AvCount Calibration Material ‘d’ - SA1121-0
AvCount Calibration Material ‘d’ - SA1121-0
Methods
ASTM D7619
IP 565
ISO 11171
IP 630
Features
- Produced under our ISO 17034 UKAS accreditation
- Homogeneity and variability is checked in accordance with ISO 11171
- Serves as a Secondary Working Standard (SWS) with a particle distribution traceable to NIST 2806d & 8631x
- Use it with Automatic Particle Counters (APCs) calibrated in accordance with ISO 11171
- Supplied in tamper-evident security packaging with full documentation, including a Safety Data Sheet (SDS)
- 2 year shelf life from the date of manufacture
- 250 mL bottle
SETA-CRM FAME
SETA-CRM FAME
Methods
ASTM D8274
IP 639
Features
- Produced under our ISO 17034 UKAS accreditation
- Consists of a hydrocarbon sample containing FAME with a certified value
- A gravimetric approach with high-accuracy ISO 17025-calibrated balances is used to ensure precise productio
- This method minimises measurement uncertainties associated with characterisation
- Supplied with full documentation including Safety Data Sheet (SDS)
- 2 year shelf life from date of manufacture
Setavap 2 Vapour Pressure Tester - 81000-2
Setavap 2 Vapour Pressure Tester - 81000-2
Methods
BIS IS 1448-39
ASTM D5191
BS EN 13016-1 & BS 2000-394
Correlates with: ASTM D323 & ASTM D4953 & ASTM D5482 & ASTM D6378 & IP 69 & BS ISO 3007 & BS 2000-69
IP 481
Features
Features
- Rapid and automatic testing
- "Mini" method uses 3 ml sample size
- Selectable units - kPa or psi
- Results available as Ptot, DVPE, Crude, Pabs
SETA-CRM Pensky-Martens Flash Point
SETA-CRM Pensky-Martens Flash Point
Methods
ASTM D4052
ASTM D93
EN ISO 2719
IP 34
IP 365
ISO 12185
Features
- Produced under our ISO 17034 UKAS accreditation
- Pack of 3 with nominal values of 75 C, 140 C, 225 C
- This hydrocarbon mixture carries certification for Flash Point determination (ASTM D93, IP 34, ISO 2719) and Density measurement (ASTM D4052, IP 365, ISO 12185)
- An Interlaboratory Study characterises the reference material, guaranteeing international traceability and lower-than-average uncertainty
- Laboratories seeking ISO 17025 compliance will find this cost-effective solution simplifies verification processes
- Supplied in a tamper-evident security package with full documentation, including a Safety Data Sheet (SDS)
- 3 year shelf life from the date of manufacture
Vapour Pressure – Certified Reference Material, Pentane 200 ml - 80610-0
Vapour Pressure – Certified Reference Material, Pentane 200 ml - 80610-0
Methods
ASTM D5191
ASTM D6378
BS EN 13016-1 & BS 2000-394
EN 13016-3
Features
Features
- Suitable for verification of Setavap and other mini method instruments
- Determines the vapour pressure of volatile liquid petroleum products, ethanol blends, hydrocarbons and hydrocarbon-oxygenate mixtures
Thermometer Digital: Precision -199 to 199 °C - 51000-0
Thermometer Digital: Precision -199 to 199 °C - 51000-0
Methods
Features
Features
- -199 to 199 °C
- Excellent precision
- Fast response time
- Compact design
- Traceable calibration in accordance with ASTM E1137 and ASTM E2877 specifications
Digital Thermometer High Range -199 to 300 °C - 51005-0
Digital Thermometer High Range -199 to 300 °C - 51005-0
Methods
Features
Features
- High range temperature measurement
- -199.9 to +300ºC
- +/- 0.5 ºC precision
- Compact design
- Traceable calibration in accordance with ASTM E1137 and ASTM E2877
Non Hazardous Thermometer ASTM9C - ASTMST9C
Non Hazardous Thermometer ASTM9C - ASTMST9C
Methods
ASTM D93
Features
Features
- -5 to +110 ºC
- Non-hazardous
- Same dimensions as traditional Hg thermometers
- Easy to clean up in the event of breakage
- Visually different from Hg (blue filling)
Thermometer ASTMS5C: Low Hazard - ASTMS5CX
Thermometer ASTMS5C: Low Hazard - ASTMS5CX
Methods
ASTM D2500
ASTM D97
ASTM E2251
Features
Features
- Same dimensions as traditional Hg thermometers
- Easy to clean up in the event of breakage
- Visually different from Hg (blue)
- Classified as non-hazardous for shipping